Plus Icons

Separation of Lithium Isotopes by Aminobenzo-15-Crown-5 …

Elution chromatographic separation of lithium isotopes was carried out with aminobenzo-15-crown-5 bonded merrifield resin. This resin have a capacity of 0.24 meq/g dry resin. By column chromatography using 1.0M NH4Cl solution as an eluent, a single separation factor 1.026 was obtained from the elution curve and isotope ratios according to the …

به خواندن ادامه دهید
Plus Icons

26: Introduction to Chromatographic Separations

In this chapter we provide a general introduction to chromatographic separations. In the four chapters that follow, we will consider specific chromatographic methods. 26.1: A General Description of Chromatography. In chromatography we pass a sample-free phase, which we call the mobile phase, over a second sample-free stationary phase that ...

به خواندن ادامه دهید
Plus Icons

Lithium isotope separation using displacement …

Lithium isotope separation. Cation exchange. Resin cross-linkage effect. Displacement chromatography. 1. Introduction. Tritium is expected to be used as fuel in …

به خواندن ادامه دهید
Plus Icons

12.5: High-Performance Liquid Chromatography

In high-performance liquid chromatography (HPLC) we inject the sample, which is in solution form, into a liquid mobile phase. The mobile phase carries the sample through a packed or capillary column that separates the sample's components based on their ability to partition between the mobile phase and the stationary phase.

به خواندن ادامه دهید
Plus Icons

12.7: Electrophoresis

Figure 12.57 compares the electroosmotic flow profile with that the hydrodynamic flow profile in gas chromatography and liquid chromatography. The uniform, flat profile for electroosmosis helps minimize band broadening in capillary electrophoresis, improving separation efficiency. Figure 12.57: Comparison of hydrodynamic flow and …

به خواندن ادامه دهید
Plus Icons

The Messenger: mRNA purification | Cytiva

The downside is that aberrant RNAs aren't removed, which is why this step is usually followed by another chromatography step. Anion exchange chromatography (AEX) is an attractive option for polishing, because it provides good separation of single-stranded mRNA from immunogenic DNA, RNA-DNA hybrids, dsRNA, and other aberrant …

به خواندن ادامه دهید
Plus Icons

Ion chromatographic determination of hydrolysis products of

In this work, hydrolysis of three different hexafluorophosphate salts in purified water was investigated. Aqueous samples of lithium hexafluorophosphate (LiPF 6), sodium hexafluorophosphate (NaPF 6) and potassium hexafluorophosphate (KPF 6) were prepared and stored for different times.Ion chromatography (IC) with UV as well as non …

به خواندن ادامه دهید
Plus Icons

Separation of lithium isotopes by crown ether-room …

Solvent extractive separation of lithium isotopes is expected to become an alternative for lithium amalgam electrolysis separation processes due to its evident …

به خواندن ادامه دهید
Plus Icons

Ion Chromatography Assay for Lithium in Lithium …

This method uses ion chromatography (IC) and offers significant improvement over existing assays because it can simultaneously determine lithium, sodium, calcium, and other …

به خواندن ادامه دهید
Plus Icons

Extraction separation of lithium isotopes with

The laws of extraction separation of lithium isotopes effects of ionic liquids and lithium salts, crown ether concentration, and temperature on the separation performance of lithium isotopes were explored. ... Lithium isotope separation with displacement chromatography using crown ether resin immobilized on porous silica …

به خواندن ادامه دهید
Plus Icons

Liquid-Liquid Extraction and Chromatography Process Routes for …

the separation of lithium from other alkali metal ions by reversed phase chromatography (74). After After loading the feed in basic conditions, using KOH or NH 4 OH, lithium was eluted using ...

به خواندن ادامه دهید
Plus Icons

Chromatographic Techniques in the Research Area of …

Two-dimensional ion chromatography for the separation of ionic organophosphates generated in thermally decomposed lithium hexafluorophosphate …

به خواندن ادامه دهید
Plus Icons

Novel Syntheses Method of Phenol Type Benzo-15-Crown-5 …

tography of lithium isotope separation for following reasons that the swelling of resin is generally occurred by adding the methanol, the adsorption of lithium is relatively high in above condition, and the same solvent condition was adopt-ed in the previous work.5) 2. Chromatography of Lithium Isotope Separation (1) Chromatographic Experiment

به خواندن ادامه دهید
Plus Icons

Separation of lithium isotopes: Electromigration coupling …

6 Li and 7 Li, two natural isotopes of lithium, play an important role in the nuclear industry. Here, a system of ionic liquid-crown ether was fabricated for lithium …

به خواندن ادامه دهید
Plus Icons

Ion Chromatography Assay for Lithium in Lithium Citrate

Separation Separation of lithium was achieved using a Dionex IonPac CS12A, 3 x 150 mm column under gradient elution conditions. Figure 2 ... Ion Chromatography Assay for Lithium in Lithium Citrate Sachin Patil, Jeffrey Rohrer Thermo Fisher Scientific, Sunnyvale, CA, USA 94085 5. 1 5 5

به خواندن ادامه دهید
Plus Icons

Separation of lithium and magnesium isotopes by hydrous manganese…

Lithium and magnesium isotopes were separated by chemical ion exchange using hydrous manganese(IV) oxide and elution chromatography. The capacity of manganese(IV) oxide was 0.5 meq/g. The glass ion exchange column used was 35 cm long with an inner diameter of 0.2 cm, and 2.0M CH3COONH4 solution served as eluent. The single stage …

به خواندن ادامه دهید
Plus Icons

Separative analyses of a chromatographic column packed with a …

A core-shell type adsorbent was proposed for lithium isotope separation by chromatography. The mass transfer model in a chromatographic column consisted of 4 steps, such as convection and dispersion in the column, transfer through liquid films, intra-particle diffusion and and adsorption or desorption at the local adsorption sites.

به خواندن ادامه دهید
Plus Icons

Separation of lithium isotopes by elution …

Separation of lithium isotopes by elution chromatography with an AB18C6 bonded Merrifield peptide resin. D. W. Kim,1* B. M. Kang,1B. K. Jeon,1Y. S. Jeon2. 1Department …

به خواندن ادامه دهید
Plus Icons

Sensitive and direct determination of lithium by mixed …

Chromatographic separation space and conditions of lithium analysis. The studies showed a clear separation space where drug matrix, anions and other cations are separated from lithium. Fig. 1 shows that the separation between lithium and other ions …

به خواندن ادامه دهید
Plus Icons

Separation techniques: Chromatography

Four separation techniques based on molecular characteristics and interaction type use mechanisms of ion exchange, surface adsorption, partition, and size exclusion. Other chromatography techniques are based on the stationary bed, including column, thin layer, and paper chromatography. Column chromatography is one of the …

به خواندن ادامه دهید
Plus Icons

Lithium isotope effect in extraction of lithium chloride by 4

Abstract The lithium isotope separation (LIS) plays a vital role in development of nuclear industry. The liquid–liquid extraction technologies open up new possibilities for LIS. This work presents preliminary results of the study on the extractions and separation of 6Li/7Li by mixed system, comprising amino-derivatives of benzo-15 …

به خواندن ادامه دهید
Plus Icons

Ion chromatographic separations of phosphorus species: a review

Depending on the modification, two different separation chromatographic modes are obtained: ion-interaction chromatography and electrostatic ion chromatography [45], [46]. Applications of both modes to phosphate analysis are described in the following section. ... lithium, and potassium) of hydroxide solutions, providing …

به خواندن ادامه دهید
Plus Icons

High‐precision determination of lithium and magnesium isotopes

3.1 Chromatographic separation of lithium and magnesium. Lithium and magnesium are quantitatively separated from elements such as Na, K, Al, Ti, Mn, Fe, Ca, Sr and Ba by our column elution protocol using the AGMP-50 resin. There is a 10 mL separation between Li and Na for Li masses ranging from 0.3 to 20 ng (Figure 1).

به خواندن ادامه دهید
Plus Icons

Extraction Chromatography for Separation of Rare Earth …

Rare earth elements (REEs) are identified by the EU as critical resources, and moreover, they are difficult to separate due to their similar properties. Extraction chromatography is a powerful method suitable for difficult, high-purity separations, which could form part of a separation process for recovery of REEs from various sources.

به خواندن ادامه دهید
Plus Icons

Polysulfone-graft-4′- aminobenzo-15-crown-5-ether

An elution chromatography method, using ultrapure water as eluent and LiI as lithium salt (1000 mg/L), was employed to evaluate the performance of membrane chromatography for the adsorptive separation of lithium isotopes. Furthermore, a four-stage tandem membrane chromatography system was designed to enhance the …

به خواندن ادامه دهید
Plus Icons

Study on behavior of lithium ion in solvent extraction and isotope

Controlled fusion energy is considered to be one kind of sustainable energy source with clean and green properties. The fusion process requires a large number of lithium isotopes, but the naturally stable lithium isotopes 6 Li and 7 Li cannot be directly applied to the fusion process and must be further enriched. In this paper, a system for …

به خواندن ادامه دهید
Plus Icons

Applications of Poly(Ethylene)Glycol (PEG) in Separation Science …

In separation science, PEGs have been utilized as diluents [], precipitating agents [], extraction solvents [], stationary phases [], or mobile phase modifiers [].This class of compounds was used for decades in protein crystallization to enable X-ray diffraction analysis [].PEG is still widely applied in liquid chromatography (LC) [], gas …

به خواندن ادامه دهید
Plus Icons

Sample Preparation for Chromatographic Purification

Buffer for first purification step. Filter (0.45 μm) or centrifuge the sample (10 000 ×g at 4 °C). Add 1 part 1 M Tris-HCl, pH 8.0 to 10 parts sample volume to maintain pH. Stir gently. Add ammonium sulfate solution, drop by drop. Add up to 50% saturation*. Stir for 1 hour. Centrifuge 20 min at 10 000 ×g.

به خواندن ادامه دهید
Plus Icons

Oligonucleotide separation techniques for purification and …

For DNA separation of 100 bp → 5 kb, 10 mM sodium boric acid and for >3 kb 5 mM lithium acetate were recommended, whereas for RNA separation, it was 5 mM sodium boric acid or 5 mM lithium acetate. ... Because ion-pairing reagents are needed for chromatographic separation, the influence on MS sensitivity concerned the authors.

به خواندن ادامه دهید

آیا هیچ سوالی دارید ؟

چه بخواهید با ما کار کنید و چه علاقه مند به کسب اطلاعات بیشتر در مورد محصولات ما هستید، مایلیم از شما بشنویم.